<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40410</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Plates are sticking together.  Please open the plate cover and separate the plates.  Press RESUME to continue.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If this error is reported, the picker wrist is having trouble moving out, most likely because the
plates are stuck together.
</text></DescriptionText>
<DescriptionText><text>
If there are problems during a pick, the firmware does extra steps to try and figure out the real
problem.  For this error to be reported, the picker will have tried to grab the plate, but could not
wrist out with it, either because it popped off while the picker was wristing out, or because the
wrist didn not move out within the allowed time.  The picker wrist will have moved back in to try and
grab the plate again.  If, after the second try, the picker still cannot wrist the plates out, this
error will be reported.
</text></DescriptionText>
<DescriptionText><text>
The wrist cylinder may be faulty, but after the wrist failed to move out the first time, the vacuum
will have been released.  After releasing the plate, the wrist moved out properly.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The plates in the device are probably sticking together, preventing the loading sequence to complete.
Please open the plate cover and try to separate the plates.  Close the plate cover, then press the
RESUME button to contine the loading sequence.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The plates are sticking together, causing the picker to have trouble moving the wrist out.
</Cause>
<Cause>
The timeout value for the wrist motion (aldly pwod) could be too short.
</Cause>
<Cause>
The wrist cylinder may be sticking, or moving slowly.
</Cause>
<LastModified>
18-DEC-2001
Created.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:26 2008 PST
</Updated>
<Links>
</Links>
</Error>